Parameter Dictionary Parameters
Motor Continuous Torque. Units: 0.00001 Nm units.
Motor Max Velocity. Units: 0.1 encoder counts/s.
Motor Wiring. 0=standard, 1= drive’s U and V outputs are swapped.
Motor Hall Offset. Offset angle to be applied to the Hall sensors. Units: degrees.
The type of Hall effect sensors attached to the motor:
No Hall sensors available.
Motor Hall Wiring. Bit-mapped as follows:
NOTE: When analog Halls are used, only bit 8 is relevant.
The Hall wiring code (see below).
1 U W V
3 Reserved.
Invert W Hall input if set. Inversion occurs after Halls wiring is changed by bits 0-2.
Invert V Hall input if set. Inversion occurs after Halls wiring is changed by bits 0-2.
Invert U Hall input if set. Inversion occurs after Halls wiring is changed by bits 0-2.
Reverse analog Halls if set.
9-15 Reserved.
Copley Controls Page 18