Control Panel CME 2 User Guide
148 Copley Controls
14.1: Control Panel Overview
Each of the Control Panel features labeled below is described in the sections that follow.
Red if fault
is active
Yellow if warning
is active
Display error log
Message box
Control functions
Status indicators
Monitor real-time amplifier values
and operational mode
Jog mode controls
14.2: Status Indicators and Messages
The Status area includes status indicator lights (described below) and a message box.
Any red lights indicate that motion will be inhibited.
State of the safety circuit. Enabled or HI/LO disabled. On amplifiers with safety circuit.
State of the PWM output stage. Red if the output stage is inactive (disabled)
State of the hardware enable input(s). Red if one or more enable inputs are inactive.
State of the software enable. Red if the amplifier is disabled by software.
State of the positive limit switch input. Red indicates an activated positive limit switch.
State of the negative limit switch input. Red indicates an activated negative limit switch.
State of the software limits. Red indicates an activated software limit.
Indicates a motor phasing error. Red indicates a motor phasing error exists.
State of the programmed Motion Abort Input. Red indicates the input is active.
Status of the CVM Control Program.
Indicates whether the axis has successfully been referenced (homed).
Status of the CAN Bus. Yellow indicates CAN warning limit reached. Red indicates bus
error detected.
Indicates whether Gain Scheduling (p. 221) is active.
The fault indicator goes red when a fault is active. Check the status message box for a
description of the most recent fault: .
Check the Error Log for a full history of faults and warnings.
The warning indicator goes yellow when a warning is active. Check the status message
box for a description of the most recent: .
Check the Error Log for a full history of faults and warnings.
Displays status descriptions.