10.1: Phase Motor with Auto Phase
Choose the appropriate procedure:
Auto Phase Example: Servo Amplifier (p. 94)
Auto Phase Example: Stepper Amplifier, No Encoder (p. 98)
Auto Phase Example: Stepper Amplifier with Encoder, in Stepper Mode (p. 99)
Auto Phase Example: Stepper Amplifier with Encoder, in Servo Mode (p. 100)
NOTE: The examples in this chapter show particular amplifier operating modes and motor
feedback configurations. Some screens and choices may vary from those described here.
10.1.1: Auto Phase Example: Servo Amplifier
Perform the following steps to Auto Phase a servo amplifier.
NOTE: The following steps show Auto Phase with a brushless rotary motor, digital Halls,
and an incremental quadrature encoder. Screens vary for other configurations.
Verify that the Enable Input is not activated and that HV or AC power is applied.
Click Auto Phase to open the Auto Phase Motor Direction Setup screen.
Move the motor in the direction to be considered positive
OR if you cannot move the motor, click Skip (you will confirm motor direction later).
NOTE: If an output is configured as a brake you can temporarily release the brake by
holding down the Release Brake button. The brake will be reactivated when you
release the button.
Click Next to open the Auto Phase Motor Wiring Setup screen: